Passer au contenu principal
CONNEXION / ENREGISTREMENT
Se connecter avec {$a}
Se connecter avec {$a}
Se connecter avec {$a}
Se connecter avec {$a}
Se connecter avec {$a}
Se connecter avec {$a}
Se connecter avec {$a}
Se connecter avec {$a}
Q-SYS Level 1 Hybrid
Formation à la demande
Q-SYS Training
Vous découvrez la formation Q-SYS ?
Q-SYS Level One (Q-SYS niveau 1)
English
Spanish
Français
German
Chinese(Mainland)
Chinese(HK,MACAU,TAIWAN)
Portuguese
Q-SYS Control 101 (Les bases de Q-SYS Control)
English
Spanish
Français
German
Chinese
Démarrages rapides Q-SYS
English
Spanish
Formation Q-SYS Quantum
Q-SYS Video 101 (Les bases de la vidéo Q-SYS)
English
Spanish
Français
Portuguese
Formation Q-SYS certifiée pour les commerciaux
Q-SYS Reflect Enterprise Manager
English
Spanish
Formation pour le cinéma
Formation de base pour le cinéma 101
Q-SYS Level One For Cinema (Q-SYS niveau 1 pour le cinéma)
Q-SYS Level Two For Cinema - Bridge Course (Q-SYS niveau 2 pour le cinéma - Cours intermédiaire)
Formation Série MP-M
English
Spanish
Portuguese
Français
Formation PLD/CXD
QSC Pro Audio Training
Vous découvrez la formation QSC Pro Audio ?
Enceintes actives line array Classe L
Tables de mixage numérique TouchMix
English
Spanish
Italian
Enceintes actives Série K.2
Enceintes actives Série CP
Line array actif KLA
Lieu de culte
Application TouchMix
Conseil de sonorisation
Live Training
Q-SYS Architect (Présentation)
Q-SYS Level One (Q-SYS niveau 1)
Q-SYS Level Two (Q-SYS niveau 2)
Standard
Enseignement supérieur
Cinéma
Q-SYS Control
Principes de base du contrôle et de l’UCI
Control 201 (Introduction à la programmation de contrôle)
Formation avancée sur l’UCI
Formation TouchMix certifiée pour les opérateurs
Contact
Français (fr)
Deutsch (de)
English (en)
Español - Internacional (es)
Français (fr)
Italiano (it)
Português - Brasil (pt_br)
Русский (ru)
简体中文 (zh_cn)
PRO AUDIO TRAINING - CLICK HERE
Menu
Formation à la demande
Q-SYS Training
Vous découvrez la formation Q-SYS ?
Q-SYS Level One (Q-SYS niveau 1)
English
Spanish
Français
German
Chinese(Mainland)
Chinese(HK,MACAU,TAIWAN)
Portuguese
Q-SYS Control 101 (Les bases de Q-SYS Control)
English
Spanish
Français
German
Chinese
Démarrages rapides Q-SYS
English
Spanish
Formation Q-SYS Quantum
Q-SYS Video 101 (Les bases de la vidéo Q-SYS)
English
Spanish
Français
Portuguese
Formation Q-SYS certifiée pour les commerciaux
Q-SYS Reflect Enterprise Manager
English
Spanish
Formation pour le cinéma
Formation de base pour le cinéma 101
Q-SYS Level One For Cinema (Q-SYS niveau 1 pour le cinéma)
Q-SYS Level Two For Cinema - Bridge Course (Q-SYS niveau 2 pour le cinéma - Cours intermédiaire)
Formation Série MP-M
English
Spanish
Portuguese
Français
Formation PLD/CXD
QSC Pro Audio Training
Vous découvrez la formation QSC Pro Audio ?
Enceintes actives line array Classe L
Tables de mixage numérique TouchMix
English
Spanish
Italian
Enceintes actives Série K.2
Enceintes actives Série CP
Line array actif KLA
Lieu de culte
Application TouchMix
Conseil de sonorisation
Vous découvrez la formation QSC Pro Audio ?
Enceintes actives line array Classe L
Tables de mixage numérique TouchMix
English
Spanish
Italian
Enceintes actives Série K.2
Enceintes actives Série CP
Line array actif KLA
Lieu de culte
Application TouchMix
Conseil de sonorisation
Vous découvrez la formation QSC Pro Audio ?
Enceintes actives line array Classe L
Tables de mixage numérique TouchMix
English
Spanish
Italian
Enceintes actives Série K.2
Enceintes actives Série CP
Line array actif KLA
Lieu de culte
Application TouchMix
Conseil de sonorisation
Live Training
Q-SYS Architect (Présentation)
Q-SYS Level One (Q-SYS niveau 1)
Q-SYS Level Two (Q-SYS niveau 2)
Standard
Enseignement supérieur
Cinéma
Q-SYS Control
Principes de base du contrôle et de l’UCI
Control 201 (Introduction à la programmation de contrôle)
Formation avancée sur l’UCI
Formation TouchMix certifiée pour les opérateurs
Contact
Français (fr)
English (en)
Deutsch (de)
Español - Internacional (es)
Français (fr)
Italiano (it)
Português - Brasil (pt_br)
Русский (ru)
简体中文 (zh_cn)
QSCID
CONNEXION / ENREGISTREMENT
Se connecter avec {$a}
Se connecter avec {$a}
Se connecter avec {$a}
Se connecter avec {$a}
Se connecter avec {$a}
Se connecter avec {$a}
Se connecter avec {$a}
Se connecter avec {$a}
CIAM Login
The Left-Side Pane
Q-SYS Level 1 Hybrid : Software Overview
Collapse all
Expand all
Close Search Results
CERTIFICATION STEPS COMPLETED
Certification Steps Completed
1 ) Hardware Overview
15m 28s
Basic Q-SYS Signal Path
3m 52s
Hardware Peripherals
5m 50s
I/O Cards
System Redundancy
2m 42s
Using CXD-Q Amplifiers
3m 4s
2 ) Software Overview
1h 8m 28s
Software Basics
10m 6s
The Inventory Panel
7m 23s
Connecting to the Core
7m 33s
Traditional Wiring & Signal Names
4m 14s
Signal Snakes & Pagination
3m 54s
Audio Components
5m 51s
The Right-Side Pane
9m 11s
The Left-Side Pane
6m 49s
Amplifiers and Loudspeakers
10m 7s
Maximizing Channel Output
3m 20s
3 ) Administrator
16m 38s
Administrator Commands
4m 40s
Tags and Command Schedule
4m 13s
Users, UCIs, & Audio Files
4m 40s
Playlists and Event Logs
3m 5s
4 ) Snapshots
3m 51s
Snapshots
3m 51s
5 ) Intro to AEC
21m 54s
Intro to Acoustic Echo Canceler
2m 55s
How does AEC work?
6m 57s
Incorporating Softphone and Contacts
12m 2s
6 ) Basic Design File
0m 0s
You're almost ready for class!
Video Transcript
Downloads and Links
Video Transcript
The Left-Side Pane
6m 49s
00:08
Welcome back!
00:09
Let’s finish up our tour of the different areas of the Q-SYS Designer Software by looking at the left-side pane.
00:15
This pane has several different panels that expand and collapse in an accordion style,
00:21
with only one open at a time.
00:23
You’ve already seen the first one—the Inventory, which contains virtual representations of all the physical
00:30
hardware devices in your design and their corresponding components.
00:33
The most important thing here is the Plus button, which allows you to add new devices from our inventory library.
00:40
The second panel, Schematic Pages, you’ve also already seen.
00:44
If you’re building a larger design
00:46
or you just want to separate different areas of your design onto different pages,
00:50
you can add those pages and rename them here.
00:53
If you close the Schematic window for any page, this is where you would go to open it up again.
00:58
So let’s move on to the User Control Interfaces pane.
01:02
This is where you build the interface that a user will interact with to control your system,
01:08
which could be deployed onto a native Q-SYS touch screen or a networked PC,
01:14
tablet, or smart phone using our Q-SYS Control app.
01:17
Like the Schematic Pages, you can use the Plus button to add new UCIs to your design and rename them,
01:24
but rather than a blank Schematic page you’ll see this: the UCI Editor window.
01:29
We’ll take a deep dive into building UCIs later in this course, but let’s glance at this at a high level.
01:36
The first thing you should do is adjust your UCI’s properties to match the type and orientation
01:42
of the screen that will eventually display it, which will adjust the footprint of your workspace
01:46
to the appropriate pixel dimensions and ratio.
01:49
The navigation bar in the UCI Editor lists all of your pages, layers, and objects.
01:55
You can use the Plus button at the bottom to create a new page or a new layer on an existing page,
02:02
and later you’ll learn some options on different ways to navigate these pages and layers.
02:07
You can add controls to your UCI simply by dragging them
02:11
either from the schematic itself or using the copy and paste tools.
02:15
You can add graphics to the UCI by dragging an image file from any file browser
02:21
and you’ll see these all itemized in your navigation bar,
02:24
where you can lock them, change their visibility, or adjust their order.
02:29
You can get very creative with the design of your UCI, which—again—we’ll explore in later videos.
02:36
The next panel is where you’ll find your Snapshots,
02:39
which is also a topic that’s covered in a video later in this course.
02:42
Snapshots are essentially a recording of the states of one or more controls,
02:48
which allow you to recall those controls to their saved states with a single button.
02:52
You could have many different Snapshot Banks in your design which all manage different sets of controls.
02:57
You also have a Global Snapshot Bank which you should use with extreme caution,
03:01
because it can change every single control in the entire design.
03:05
Even after you learn how to use Snapshots, be careful when using Global Snapshots.
03:11
Next we have Named Controls.
03:13
You can drag any control into the Named Controls Bin,
03:17
which allows it to be accessed by something that’s not wired to your control in the Schematic.
03:22
For instance, you could reference a Named Control from within a Lua script or a Block Controller code.
03:29
You could change a Named Control from within the Administrator tool,
03:33
which lets you schedule events to occur at a particular time of day.
03:36
You could even use a third-party control processor to send commands to your Q-SYS Core over the network,
03:42
which could target your Named Controls.
03:45
Basically, this bin is the window to allow something outside of your Schematic
03:50
to control something inside your Schematic.
03:53
You should also note that if you need to export this list of controls,
03:57
you can select Tools > Extract Named Controls and get an XML file of these available controls.
04:04
It’s also worth noting that a Named Control might have a very ugly name when you drag it in,
04:10
so feel free to rename it; as doing so won’t change its link to your original control.
04:16
And as always, if you forget where a control came from, you can press Control+F to track it to its original source.
04:26
Finally, we have the Inspector, which can check your design for any obvious errors.
04:31
No, it can’t tell you whether you’ve done a good job tuning your audio,
04:36
but it can locate certain undeniable mistakes.
04:39
For instance, if you’re using any scripting components or plugins, it will monitor those for any coding faults,
04:46
and you can track those back to the component that is having an issue.
04:49
The Inspector also searches for Orphaned Controls,
04:53
which is a control that has lost its parent component and now delivers justice at night as a masked vigilante.
05:01
A control might become orphaned if you’ve dragged it out of its control panel onto your UCI, for instance,
05:07
and then later deleted that original component.
05:10
The copy of the control still exists, but it will have a large question mark on it alerting you
05:15
that it is no longer is linked to any component, and the Inspector will warn you of its orphaned status.
05:22
The Inspector will also notify you of any Unterminated Signals,
05:27
which are signals that have not yet been murdered by robots from the future.
05:31
Or, in the world of wiring, a terminated wire is something that is connected to a terminal,
05:37
and thus an unterminated wire is one that has not been completed.
05:41
If you create a signal tag for a wire but you fail to finish that connection somewhere else,
05:47
then that tag will have a jagged edge as a warning,
05:50
and your Inspector will notify you that the connection is incomplete.
05:57
The last thing the Inspector does is keep track of any functions
06:01
in your design that require a Core feature license.
06:05
If you’ve built a UCI, for instance,
06:07
it will remind you that your Core will need a UCI Deployment feature license in order to operate.
06:12
The same is true with any scripting elements or plugins that require a Scripting feature license.
06:18
If these or any other licenses are required,
06:21
you’ll see a yellow lock icon as well as a notification in the top menu bar to remind you to get these licenses
06:28
installed on your Core, or else that design will not be able to run on it.
06:32
Alright, that’s it for the walkthrough of the various areas of the software itself.
06:37
Next we’ll start digging into some specific features and concepts,
06:41
and hopefully you should be familiar enough with navigating the software to follow along.
06:45
Thanks for watching.
Downloads and Links
The Left-Side Pane
6m 49s
Download the video: "The Left-Side Pane"
Download Q-SYS Designer
administration
Résumé de conservation de données