Passer au contenu principal
CONNEXION / ENREGISTREMENT
Se connecter avec {$a}
Se connecter avec {$a}
Se connecter avec {$a}
Se connecter avec {$a}
Se connecter avec {$a}
Se connecter avec {$a}
Se connecter avec {$a}
Se connecter avec {$a}
Q-SYS Quantum Level ...
Formation à la demande
Q-SYS Training
Vous découvrez la formation Q-SYS ?
Q-SYS Level One (Q-SYS niveau 1)
English
Spanish
Français
German
Chinese(Mainland)
Chinese(HK,MACAU,TAIWAN)
Portuguese
Q-SYS Control 101 (Les bases de Q-SYS Control)
English
Spanish
Français
German
Chinese
Démarrages rapides Q-SYS
English
Spanish
Formation Q-SYS Quantum
Q-SYS Video 101 (Les bases de la vidéo Q-SYS)
English
Spanish
Français
Portuguese
Formation Q-SYS certifiée pour les commerciaux
Q-SYS Reflect Enterprise Manager
English
Spanish
Formation pour le cinéma
Formation de base pour le cinéma 101
Q-SYS Level One For Cinema (Q-SYS niveau 1 pour le cinéma)
Q-SYS Level Two For Cinema - Bridge Course (Q-SYS niveau 2 pour le cinéma - Cours intermédiaire)
Formation Série MP-M
English
Spanish
Portuguese
Français
Formation PLD/CXD
QSC Pro Audio Training
Vous découvrez la formation QSC Pro Audio ?
Enceintes actives line array Classe L
Tables de mixage numérique TouchMix
English
Spanish
Italian
Enceintes actives Série K.2
Enceintes actives Série CP
Line array actif KLA
Lieu de culte
Application TouchMix
Conseil de sonorisation
Live Training
Q-SYS Architect (Présentation)
Q-SYS Level One (Q-SYS niveau 1)
Q-SYS Level Two (Q-SYS niveau 2)
Standard
Enseignement supérieur
Cinéma
Q-SYS Control
Principes de base du contrôle et de l’UCI
Control 201 (Introduction à la programmation de contrôle)
Formation avancée sur l’UCI
Formation TouchMix certifiée pour les opérateurs
Contact
Français (fr)
Deutsch (de)
English (en)
Español - Internacional (es)
Français (fr)
Italiano (it)
Português - Brasil (pt_br)
Русский (ru)
简体中文 (zh_cn)
PRO AUDIO TRAINING - CLICK HERE
Menu
Formation à la demande
Q-SYS Training
Vous découvrez la formation Q-SYS ?
Q-SYS Level One (Q-SYS niveau 1)
English
Spanish
Français
German
Chinese(Mainland)
Chinese(HK,MACAU,TAIWAN)
Portuguese
Q-SYS Control 101 (Les bases de Q-SYS Control)
English
Spanish
Français
German
Chinese
Démarrages rapides Q-SYS
English
Spanish
Formation Q-SYS Quantum
Q-SYS Video 101 (Les bases de la vidéo Q-SYS)
English
Spanish
Français
Portuguese
Formation Q-SYS certifiée pour les commerciaux
Q-SYS Reflect Enterprise Manager
English
Spanish
Formation pour le cinéma
Formation de base pour le cinéma 101
Q-SYS Level One For Cinema (Q-SYS niveau 1 pour le cinéma)
Q-SYS Level Two For Cinema - Bridge Course (Q-SYS niveau 2 pour le cinéma - Cours intermédiaire)
Formation Série MP-M
English
Spanish
Portuguese
Français
Formation PLD/CXD
QSC Pro Audio Training
Vous découvrez la formation QSC Pro Audio ?
Enceintes actives line array Classe L
Tables de mixage numérique TouchMix
English
Spanish
Italian
Enceintes actives Série K.2
Enceintes actives Série CP
Line array actif KLA
Lieu de culte
Application TouchMix
Conseil de sonorisation
Vous découvrez la formation QSC Pro Audio ?
Enceintes actives line array Classe L
Tables de mixage numérique TouchMix
English
Spanish
Italian
Enceintes actives Série K.2
Enceintes actives Série CP
Line array actif KLA
Lieu de culte
Application TouchMix
Conseil de sonorisation
Vous découvrez la formation QSC Pro Audio ?
Enceintes actives line array Classe L
Tables de mixage numérique TouchMix
English
Spanish
Italian
Enceintes actives Série K.2
Enceintes actives Série CP
Line array actif KLA
Lieu de culte
Application TouchMix
Conseil de sonorisation
Live Training
Q-SYS Architect (Présentation)
Q-SYS Level One (Q-SYS niveau 1)
Q-SYS Level Two (Q-SYS niveau 2)
Standard
Enseignement supérieur
Cinéma
Q-SYS Control
Principes de base du contrôle et de l’UCI
Control 201 (Introduction à la programmation de contrôle)
Formation avancée sur l’UCI
Formation TouchMix certifiée pour les opérateurs
Contact
Français (fr)
English (en)
Deutsch (de)
Español - Internacional (es)
Français (fr)
Italiano (it)
Português - Brasil (pt_br)
Русский (ru)
简体中文 (zh_cn)
QSCID
CONNEXION / ENREGISTREMENT
Se connecter avec {$a}
Se connecter avec {$a}
Se connecter avec {$a}
Se connecter avec {$a}
Se connecter avec {$a}
Se connecter avec {$a}
Se connecter avec {$a}
Se connecter avec {$a}
CIAM Login
Introduction to Q-SYS Control (Part 4)
Q-SYS Quantum Level 1 Training (Online) : Introduction to Q-SYS Control
Collapse all
Expand all
Close Search Results
CERTIFICATION STEPS COMPLETED
Certification Steps Completed
1 ) Best Practices in Gain Structure
21m 15s
Best Practices in Q-SYS Gain Structure (Part 1)
5m 10s
Best Practices in Q-SYS Gain Structure (Part 2)
5m 7s
Best Practices in Q-SYS Gain Structure (Part 3)
5m 10s
Best Practices in Q-SYS Gain Structure (Part 4)
5m 48s
Assessment
2 ) AEC & Q-SYS Conferencing System
28m 8s
AEC & Q-SYS Conferencing System (Part 1)
6m 13s
AEC & Q-SYS Conferencing System (Part 2)
6m 25s
AEC & Q-SYS Conferencing System (Part 3)
5m 26s
AEC & Q-SYS Conferencing System (Part 4)
10m 4s
Assessment
3 ) Advanced Digital Video
27m 23s
Advanced Digital Video (Part 1)
5m 17s
Advanced Digital Video (Part 2)
9m 56s
Advanced Digital Video Part 3)
5m 6s
Advanced Digital Video (Part 4)
7m 4s
Assessment
4 ) VOIP Telephony
24m 23s
Intro to VoIP Telephony (Part 1)
7m 19s
Intro to VoIP Telephony (Part 2)
7m 2s
Intro to VoIP Telephony (Part 3)
6m 43s
Intro to VoIP Telephony (Part 4)
3m 19s
Assessment
5 ) Analog Telephony (POTS)
21m 32s
Analog Telephony (Part 1)
8m 16s
Analog Telephony (Part 2)
7m 3s
Analog Telephony (Part 3)
6m 13s
Assessment
6 ) Q-SYS Networking I
40m 20s
Quantum Networking (Part 1)
9m 13s
Quantum Networking (Part 2)
7m 2s
Quantum Networking (Part 3)
10m 23s
Quantum Networking (Part 4)
6m 10s
Quantum Networking (Part 5)
7m 32s
Assessment
7 ) Introduction to Q-SYS Control
34m 56s
Introduction to Q-SYS Control (Part 1)
6m 23s
Introduction to Q-SYS Control (Part 2)
4m 25s
Introduction to Q-SYS Control (Part 3)
10m 45s
Introduction to Q-SYS Control (Part 4)
6m 40s
Introduction to Q-SYS Control (Part 5)
6m 43s
Assessment
8 ) Q-SYS Networking II
46m 6s
Q-SYS Networking and Topologies (Part 1)
7m 48s
Q-SYS Networking and Topologies (Part 2)
4m 6s
Q-SYS Networking and Topologies (Part 3)
8m 20s
Q-SYS Networking and Topologies (Part 4)
9m 51s
Q-SYS Networking and Topologies (Part 5)
8m 49s
Q-SYS Networking and Topologies (Part 6)
7m 12s
Assessment
9 ) SIP Telephony
46m 22s
Basic SIP Telephony
19m 56s
Advanced SIP Features
9m 14s
SIP Registration with Avaya
7m 7s
Advanced SIP Registration for CUCM
5m 31s
SIP Trunking with CUCM
4m 34s
Assessment
10 ) Control Troubleshooting
9m 52s
Troubleshooting Control Programming
9m 52s
Assessment
Video Transcript
Downloads and Links
Video Transcript
Introduction to Q-SYS Control (Part 4)
6m 40s
00:07
Welcome back!
00:08
Let’s take a look now at Q-SYS Ethernet control.
00:11
As we discussed earlier, we define incoming control as control coming from a device to control Q-SYS
00:19
and then the outgoing control is when the Q-SYS system is controlling an external device.
00:26
With outgoing control, if we only need a unidirectional send only control,
00:31
we can use the Command Buttons component as a simple method to send TCP, UDP,
00:37
or serial commands to a device to provide the control that we want.
00:42
Q-SYS also has monitoring components which provide a means of supervising a device simply by sending it a ping
00:49
at a particular time interval, or an SNMP query.
00:54
Q-SYS also supports bi-directional control with plugins, and if parsing response strings is required for your
01:01
control system, then block controller, scriptable controls or text controller components are available.
01:08
Please note that for firmware Q-SYS Designer Software version 7 or greater,
01:12
you will need a feature license for scripting components and the block controller.
01:16
Let’s take a look at an example of using the Ping component in a design to monitor
01:21
the network connection status of a device.
01:24
You’’ll find the Ping Component in the right side pane under Monitoring Components folder.
01:30
If we enter Emulation mode and then enter the Host Name or IP Address of the device we want to monitor,
01:37
Q-SYS will continuously send a sequence of pings to this address on the network.
01:42
As long as we receive a reply on this address, we know that this device is on the network;
01:48
now, no guarantee that the device is fully functional, but at least we know that it’s alive.
01:54
Next let’s look at the SNMP Query component.
01:57
Go ahead and exit Emulation Mode and then add the SNMP Query component to the schematic.
02:04
Then go back to Emulation Mode where we can fill out the hostname or IP address of the device.
02:12
Next, let’s add the Community parameter of the SNMP property we want to monitor
02:18
which typically is going to be a public or private one.
02:22
We will also need to fill in the OID or Object Identifier of the SNMP property.
02:29
Beside the OID parameter field, the component displays the last value received from the SNMP query.
02:37
To the right of that we have a Comparison Operator drop down list to set how we compare
02:43
the received SNMP value to the value we enter here.
02:47
So if we set the Comparison Operator to Present, any response value received will set our Status to Okay.
02:56
We can also choose “is equal to”, greater than, or less than and so on to better compare
03:03
the values received to set our Status properly as okay or as an error.
03:08
Now let’s move on to incoming control.
03:11
Here we have a bi-directional TCP communication which has two major methodologies…
03:17
which include Q-SYS external control protocol or ECP and the Q-SYS remote control protocol or QRC.
03:25
Both methods allow for incoming control of Q-SYS, but these two methods are very different.
03:32
ECP provides control access via Named Controls that you have setup in Q-SYS Designer software.
03:38
While QRC will be very familiar if you have experience with JSON.
03:43
With ECP, we establish a TCP connection to the core on port 1702 with a keep-alive function
03:50
that is necessary every minute to maintain that connection.
03:54
This communication will need a line feed or 0A hex as the end of line character.
04:00
In addition to the feedback received from the control commands sent to the core,
04:04
to setup any unsolicited feedback,
04:06
we will need to set up what we call a "change group" to make that work.
04:11
Moving over to QRC, this control method has the benefit of providing control access
04:17
to named controls as well as named components.
04:21
QRC control is enabled in the Network Services in Core Manger and utilizes port 1710 for TCP communication.
04:30
A keep-alive is required here as well, with all the commands ending in a Null or 00 Hex value
04:36
as the end of line character.
04:38
QRC can also support Change Groups to receive non-solicited component status updates.
04:44
Now, let’s look at some integration basics on a 3rd party control system that utilizes our ECP protocol.
04:51
Let’s say that you want a Crestron system to have control over a Q-SYS gain control.
04:57
Start by adding a gain control in the design schematic, give it a name like “MyGain”,
05:03
and then drag the mute and the gain controls into the Named Control pane.
05:08
This allows control to be referenced by a third party control system like Crestron.
05:13
On the Crestron side, first we will need to establish the TCP connection.
05:17
You’ll need to have ready any login Information and the IP address of the Core handy.
05:22
For proper feedback operation, we do recommend waiting at least 10 seconds after establishing
05:28
a connection to the Core before sending initialization commands such as polling for current status
05:35
and setting up Change Groups.
05:37
Once we have properly established a control connection,
05:40
we can begin controlling our Gain component by including
05:43
the Named Component parameters that we previously setup in Q-SYS Designer.
05:46
Our control communications will need to adhere to some timing rules for communication.
05:51
Remember… you should wait ten seconds after establishing a connection
05:55
before initializing communication for polling status and change groups.
05:59
You can also use redundant core controls if you need to.
06:03
Typically, 3rd party control systems will need specific programming to establish a control connection to the
06:09
Core that will also distribute that connection to individual modules
06:13
for controlling the different aspect of the design.
06:15
Also, for all controls that need auto-polling for continuous feedback,
06:20
programming will need to be included to add all of these controls to a Change Group.
06:25
On the Q-SYS side, make sure to enable Auto-Poll to allow this functionality.
06:30
Alright, we're gonna pause right there.
06:32
When we come back we're gonna take a look at third-party control plugins. See ya next time.
Downloads and Links
Introduction to Q-SYS Control (Part 4)
6m 40s
Click here to download "Part 4" video
administration
Résumé de conservation de données