Vai al contenuto principale
Log in / Register
Entra con {$a}
Entra con {$a}
Entra con {$a}
Entra con {$a}
Entra con {$a}
Entra con {$a}
Entra con {$a}
Entra con {$a}
Q-SYS Level 1 Cinema ...
Training su richiesta
Q-SYS Training
Sei nuovo/a del Training Q-SYS?
Q-SYS Level One (Q-SYS Livello Uno)
English
Spanish
French
German
Chinese(Mainland)
Chinese(HK,MACAU,TAIWAN)
Portuguese
Q-SYS Control 101 (Controllo di Q-SYS 101)
English
Spanish
French
German
Chinese
Avviamenti rapidi Q-SYS
English
Spanish
Training Q-SYS Quantum
Q-SYS Video 101
English
Spanish
French
Portuguese
Venditore Certificato Q-SYS (nuovo)
Q-SYS Reflect Enterprise Manager
English
Spanish
Training Cinema
Training Cinema 101
Q-SYS Level One For Cinema (Q-SYS Livello Uno per Cinema)
Q-SYS Level Two For Cinema - Bridge Course (Q-SYS Livello Due per Cinema - Corso Ponte)
Training Serie MP-M
English
Spanish
Portuguese
French
Training PLD & CXD
QSC Pro Audio Training
Sei nuovo/a del Training Pro Audio QSC?
Line Array attivo Classe L
Mixer digitali TouchMix
English
Spanish
Italian
Diffusori attivi serie K.2
Diffusori attivi serie CP
Line Array attivo KLA
Luoghi di culto
Applicazione TouchMix
Sound Advice (Consigli sul Suono)
Live Training
Q-SYS Architect (Introductory - Introduttivo)
Q-SYS Level One (Q-SYS Livello Uno)
Q-SYS Level Two (Q-SYS Livello Due)
Standard
Formazione superiore
Cinema
Q-SYS Control (Controllo di Q-SYS)
Control & UCI Fundamentals (Fondamenti di Controllo & Interfaccia Utente)
Control 201 (Controllo 201)
Interfaccia Utente avanzata
Training per Operatore Certificato TouchMix
Contact
Italiano (it)
Deutsch (de)
English (en)
Español - Internacional (es)
Français (fr)
Italiano (it)
Português - Brasil (pt_br)
Русский (ru)
简体中文 (zh_cn)
PRO AUDIO TRAINING - CLICK HERE
Menu
Training su richiesta
Q-SYS Training
Sei nuovo/a del Training Q-SYS?
Q-SYS Level One (Q-SYS Livello Uno)
English
Spanish
French
German
Chinese(Mainland)
Chinese(HK,MACAU,TAIWAN)
Portuguese
Q-SYS Control 101 (Controllo di Q-SYS 101)
English
Spanish
French
German
Chinese
Avviamenti rapidi Q-SYS
English
Spanish
Training Q-SYS Quantum
Q-SYS Video 101
English
Spanish
French
Portuguese
Venditore Certificato Q-SYS (nuovo)
Q-SYS Reflect Enterprise Manager
English
Spanish
Training Cinema
Training Cinema 101
Q-SYS Level One For Cinema (Q-SYS Livello Uno per Cinema)
Q-SYS Level Two For Cinema - Bridge Course (Q-SYS Livello Due per Cinema - Corso Ponte)
Training Serie MP-M
English
Spanish
Portuguese
French
Training PLD & CXD
QSC Pro Audio Training
Sei nuovo/a del Training Pro Audio QSC?
Line Array attivo Classe L
Mixer digitali TouchMix
English
Spanish
Italian
Diffusori attivi serie K.2
Diffusori attivi serie CP
Line Array attivo KLA
Luoghi di culto
Applicazione TouchMix
Sound Advice (Consigli sul Suono)
Sei nuovo/a del Training Pro Audio QSC?
Line Array attivo Classe L
Mixer digitali TouchMix
English
Spanish
Italian
Diffusori attivi serie K.2
Diffusori attivi serie CP
Line Array attivo KLA
Luoghi di culto
Applicazione TouchMix
Sound Advice (Consigli sul Suono)
Sei nuovo/a del Training Pro Audio QSC?
Line Array attivo Classe L
Mixer digitali TouchMix
English
Spanish
Italian
Diffusori attivi serie K.2
Diffusori attivi serie CP
Line Array attivo KLA
Luoghi di culto
Applicazione TouchMix
Sound Advice (Consigli sul Suono)
Live Training
Q-SYS Architect (Introductory - Introduttivo)
Q-SYS Level One (Q-SYS Livello Uno)
Q-SYS Level Two (Q-SYS Livello Due)
Standard
Formazione superiore
Cinema
Q-SYS Control (Controllo di Q-SYS)
Control & UCI Fundamentals (Fondamenti di Controllo & Interfaccia Utente)
Control 201 (Controllo 201)
Interfaccia Utente avanzata
Training per Operatore Certificato TouchMix
Contact
Italiano (it)
English (en)
Deutsch (de)
Español - Internacional (es)
Français (fr)
Italiano (it)
Português - Brasil (pt_br)
Русский (ru)
简体中文 (zh_cn)
QSCID
Log in / Register
Entra con {$a}
Entra con {$a}
Entra con {$a}
Entra con {$a}
Entra con {$a}
Entra con {$a}
Entra con {$a}
Entra con {$a}
CIAM Login
The Left-Side Pane
Q-SYS Level 1 Cinema Training : Software Overview
Collapse all
Expand all
Close Search Results
PROCEED TO FINAL EXAM
Congratulations, you have sucessfully completed the necessary assesments for this Course
Proceed to the Final Exam Page
FINAL EXAM COMPLETED
Certification Steps Completed
Proceed to the Final Exam Page
FINAL EXAM ON PROCESS
You have not sucessfully completed the Final Exam for this Course
Proceed to the Final Exam Page
1 ) Introduction to Q-SYS Level 1 for Cinema
3m 58s
Introduction to Q-SYS Level 1 Cinema Training
3m 58s
Assessment
2 ) Hardware Overview
30m 28s
Q-SYS Overview
7m 23s
Basic Signal Path
9m 33s
Q-SYS Products: Part 1
4m 22s
Q-SYS Products: Part 2
6m 28s
System Redundancy
2m 42s
Assessment
3 ) Software Overview
1h 18m 14s
Software Basics
10m 6s
The Inventory Panel
7m 23s
Connecting to the Core
7m 33s
Traditional Wiring & Signal Names
4m 14s
Signal Snakes & Pagination
3m 54s
Audio Components
5m 51s
The Right-Side Pane
9m 11s
The Left-Side Pane
6m 49s
The Matrix Mixer
9m 46s
Amplifiers and Loudpseakers
10m 7s
Maximizing Channel Output
3m 20s
Assessment
4 ) Core Manager, Administrator, and Configurator
35m 5s
Introduction
3m 46s
The Configurator
5m 48s
Core Manager: Status and Settings
5m 3s
Core Manager: Users and Audio Files
5m 11s
Core Manager: System Management
4m 33s
The Administrator
10m 44s
Assessment
5 ) Control Overview
1h 1m 54s
Introduction to Control
2m 57s
Snapshots
3m 51s
Customizing Controls
6m 30s
Control Pins
5m 40s
UCI Creation and Management
9m 51s
UCI Customization
5m 1s
Feature License Activation
4m 12s
UCI Deployment
7m 12s
User Experience Part One
8m 40s
User Experience Part Two
8m 0s
Assessment
6 ) Audio Playback
13m 10s
Audio Player Component
7m 37s
Media Management
5m 33s
Assessment
7 ) Basic Test & Measurement
15m 29s
Test and Measurement Tools
4m 58s
Troubleshooting Strategies
4m 27s
Advanced Testing Tools
6m 4s
Assessment
8 ) Monitoring and Security Considerations
17m 5s
Enterprise Manager Technician Training Introduction
4m 37s
Connecting a Q-SYS System to Q-SYS Reflect Enterprise Manager
2m 46s
Monitoring Third-Party Devices with Enterprise Manager
6m 39s
Introduction to Q-SYS Security
3m 3s
Assessment
9 ) Final Exam Overview
24m 55s
Cinema Sample Walkthrough Part 1
12m 49s
Cinema Sample Walkthrough Part 2
12m 6s
Video Transcript
Downloads and Links
Video Transcript
The Left-Side Pane
6m 49s
00:08
Welcome back!
00:09
Let’s finish up our tour of the different areas of the Q-SYS Designer Software by looking at the left-side pane.
00:15
This pane has several different panels that expand and collapse in an accordion style,
00:21
with only one open at a time.
00:23
You’ve already seen the first one—the Inventory, which contains virtual representations of all the physical
00:30
hardware devices in your design and their corresponding components.
00:33
The most important thing here is the Plus button, which allows you to add new devices from our inventory library.
00:40
The second panel, Schematic Pages, you’ve also already seen.
00:44
If you’re building a larger design
00:46
or you just want to separate different areas of your design onto different pages,
00:50
you can add those pages and rename them here.
00:53
If you close the Schematic window for any page, this is where you would go to open it up again.
00:58
So let’s move on to the User Control Interfaces pane.
01:02
This is where you build the interface that a user will interact with to control your system,
01:08
which could be deployed onto a native Q-SYS touch screen or a networked PC,
01:14
tablet, or smart phone using our Q-SYS Control app.
01:17
Like the Schematic Pages, you can use the Plus button to add new UCIs to your design and rename them,
01:24
but rather than a blank Schematic page you’ll see this: the UCI Editor window.
01:29
We’ll take a deep dive into building UCIs later in this course, but let’s glance at this at a high level.
01:36
The first thing you should do is adjust your UCI’s properties to match the type and orientation
01:42
of the screen that will eventually display it, which will adjust the footprint of your workspace
01:46
to the appropriate pixel dimensions and ratio.
01:49
The navigation bar in the UCI Editor lists all of your pages, layers, and objects.
01:55
You can use the Plus button at the bottom to create a new page or a new layer on an existing page,
02:02
and later you’ll learn some options on different ways to navigate these pages and layers.
02:07
You can add controls to your UCI simply by dragging them
02:11
either from the schematic itself or using the copy and paste tools.
02:15
You can add graphics to the UCI by dragging an image file from any file browser
02:21
and you’ll see these all itemized in your navigation bar,
02:24
where you can lock them, change their visibility, or adjust their order.
02:29
You can get very creative with the design of your UCI, which—again—we’ll explore in later videos.
02:36
The next panel is where you’ll find your Snapshots,
02:39
which is also a topic that’s covered in a video later in this course.
02:42
Snapshots are essentially a recording of the states of one or more controls,
02:48
which allow you to recall those controls to their saved states with a single button.
02:52
You could have many different Snapshot Banks in your design which all manage different sets of controls.
02:57
You also have a Global Snapshot Bank which you should use with extreme caution,
03:01
because it can change every single control in the entire design.
03:05
Even after you learn how to use Snapshots, be careful when using Global Snapshots.
03:11
Next we have Named Controls.
03:13
You can drag any control into the Named Controls Bin,
03:17
which allows it to be accessed by something that’s not wired to your control in the Schematic.
03:22
For instance, you could reference a Named Control from within a Lua script or a Block Controller code.
03:29
You could change a Named Control from within the Administrator tool,
03:33
which lets you schedule events to occur at a particular time of day.
03:36
You could even use a third-party control processor to send commands to your Q-SYS Core over the network,
03:42
which could target your Named Controls.
03:45
Basically, this bin is the window to allow something outside of your Schematic
03:50
to control something inside your Schematic.
03:53
You should also note that if you need to export this list of controls,
03:57
you can select Tools > Extract Named Controls and get an XML file of these available controls.
04:04
It’s also worth noting that a Named Control might have a very ugly name when you drag it in,
04:10
so feel free to rename it; as doing so won’t change its link to your original control.
04:16
And as always, if you forget where a control came from, you can press Control+F to track it to its original source.
04:26
Finally, we have the Inspector, which can check your design for any obvious errors.
04:31
No, it can’t tell you whether you’ve done a good job tuning your audio,
04:36
but it can locate certain undeniable mistakes.
04:39
For instance, if you’re using any scripting components or plugins, it will monitor those for any coding faults,
04:46
and you can track those back to the component that is having an issue.
04:49
The Inspector also searches for Orphaned Controls,
04:53
which is a control that has lost its parent component and now delivers justice at night as a masked vigilante.
05:01
A control might become orphaned if you’ve dragged it out of its control panel onto your UCI, for instance,
05:07
and then later deleted that original component.
05:10
The copy of the control still exists, but it will have a large question mark on it alerting you
05:15
that it is no longer is linked to any component, and the Inspector will warn you of its orphaned status.
05:22
The Inspector will also notify you of any Unterminated Signals,
05:27
which are signals that have not yet been murdered by robots from the future.
05:31
Or, in the world of wiring, a terminated wire is something that is connected to a terminal,
05:37
and thus an unterminated wire is one that has not been completed.
05:41
If you create a signal tag for a wire but you fail to finish that connection somewhere else,
05:47
then that tag will have a jagged edge as a warning,
05:50
and your Inspector will notify you that the connection is incomplete.
05:57
The last thing the Inspector does is keep track of any functions
06:01
in your design that require a Core feature license.
06:05
If you’ve built a UCI, for instance,
06:07
it will remind you that your Core will need a UCI Deployment feature license in order to operate.
06:12
The same is true with any scripting elements or plugins that require a Scripting feature license.
06:18
If these or any other licenses are required,
06:21
you’ll see a yellow lock icon as well as a notification in the top menu bar to remind you to get these licenses
06:28
installed on your Core, or else that design will not be able to run on it.
06:32
Alright, that’s it for the walkthrough of the various areas of the software itself.
06:37
Next we’ll start digging into some specific features and concepts,
06:41
and hopefully you should be familiar enough with navigating the software to follow along.
06:45
Thanks for watching.
Downloads and Links
The Left-Side Pane
6m 49s
Download the video: "The Left-Side Pane"
Download Q-SYS Designer
administration
Riepilogo della conservazione dei dati